non-standard management syatem can be customized and developed according to customer requirements.
NO | Category | Parameter |
---|---|---|
1 | Operating temperature rangr(℃) | -40℃∽-85℃ |
2 | System startup time(mS) | 500 |
3 | Cell voltage acquisition accuracy(mV) | < ±8 |
4 | Cell voltage sampling period(mS) | < 10 |
5 | Cell temperature acquisition accuracy(℃) | Detection range:-38℃∽80℃,error vaule < 1.5℃; Detection range:80℃∽120℃,error vaule < 2℃ |
6 | Pack voltage acquisition accuracy | ≤ ±0.5%FS |
7 | Current sampling accuracy | ≤ ±0.5%FS |
8 | Controller Power Consumption(mA) | < 33mA(4W) |
9 | Operating voltage range(V) | 6-32V |
10 | MAX.Balanced current(mA) | 50mA |
11 | CAN baud rate | 250K |
12 | MAX.Driving current | 3 |
13 | insulation resistance Deetion Accuracy | Detection range:1-20mA,error vaule < ±1.5mA; Detection range:> 20mA,error vaule < ±10% |